Instant noodle ham sausage when eating rice in Anhui 12-year-old boy got stomach cancer doctor: all parents are too used to

As people's living conditions have improved and health awareness has increased, most people know that fast foods and snacks do not have much nutritional value, but there are still some parents who are accustomed to children and let them eat foods that are good but not healthy. Boy Xiaoming (a pseudonym) in Anhui Province is like this. From urine, he eats ham and instant noodles as a meal and drinks as water. Unfortunately, in the 12-year-old year, Xiao Ming was diagnosed with advanced gastric cancer.

Description: Instant noodles ham when eating 12-year-old boy had stomach cancer

Xiaoming family in the rural areas around Hefei, his family loved him very much, because the family's economic conditions are not very good, the family hopes he “eats” no worse than other children.

Ham, instant noodles, small breads, small snacks, drinks of various tastes... As long as Xiao Ming wants to eat, his family will immediately pay for it. Over time, Xiaoming did not want to touch another meal in his home. He would eat ham and instant noodles all day long, and drink it as water.

Can eat, drink and drink, Xiaoming does not see long meat but more and more thin, it is vomiting, blood in the stool and so on.

Until Xiaoming was sent to the First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, deputy chief physician Li Chonghui at the time of treatment, it was already advanced gastric cancer.

Faced with such a young child suffering from stomach cancer, Li Chonghui said: "All of us are too used to the family."

Reminder: Gastrointestinal cancer is mostly eaten and leftovers are eaten.

"The impact of diet is very large, it can be said that most of the digestive tract tumors are 'eaten'." Li Chonghui said. In particular, children like to eat good-tasting, bright-colored foods such as instant noodles, ham, candied fruit, and sweet drinks. On the one hand, the excessive sugar content of these foods, the child's physical development is not good, easily lead to obesity, on the other hand, which contains food additives, preservatives, may generate carcinogenic substances.

In addition to foods and beverages containing additives and preservatives, Li Chonghui reminded them to eat less, such as leftovers and pickled products.

"The leftovers, especially the leftover vegetables, must not be eaten. Some people have done experiments. After a certain period of frying, the nitrite content in the vegetables will rise." Li Chonghui reminded, long-term nitrite It has been considered as a carcinogen.

Patient Monitor

Features
10.1 inch high resolution color TFT display
Lightweight and portable design suitable for Ambulance,Emergency Transport
Three Working Modes : Monitoring , Surgery and Diagnosis.
Simple and friendly operating display interface.
Multi-display modes suitable for different applications: Standard Interface , Large font , ECG Standard Full Display ,OXY, Trend able BP Trend.
Built-in high capacity battery up to 3 hours of continuous work


Technique Specification
ECG

Lead Mode : 5 Leads ( I , ll , Ill , AVR , AVL , AVF , V )
Gain : 2.5mm / mV, 5.0mm /mV , 10mm /Mv, 20mm /mV
Heart Rate : 15-300 BPM ( Adult ) ; 15-350 BPM ( Neonatal )
Resolution : 1 BPM
Accuracy : ± 1%
Sensitivity > 200 uV ( Peak to peak )
ST measurement range : -2.0 ~+ 2.0 Mv
Accuracy : -0. 8mV~+ 0. 8mV : ± 0. 02mV or ± 10% , which is greater
Other Range : unspecified
Sweep speed : 12.5 mm / s , 25mm / s , 50mm / s
Bandwidth:
Diagnostic : 0.05~130 Hz
Monitor : 0.5~40 Hz
Surgery : 1~20 Hz

SPO2
Measuring Range : 0 ~ 100%
Resolution : 1%
Accuracy : 70%~100% ( ± 2 % )
Pulse Rate : 20-250 BPM
Resolution : 1 BPM
Accuracy : ± 3 BPM

Optinal Parameters :
Central monitoring system
Dual IBP
Etco 2
12-lead ECG
Nellcor SpO2
Sun Tech NIBP

NIBP
Method : Oscillometry
Measure mode Manual, Auto, STAT
Unit : mmHg , kPa
Measure and alarm range:
Adult Mode
SYS 40 ~ 280 mmHg
DIA 10 ~ 225 mmHg
MEAN 20 ~ 240 mmHg

Pediatric Mode
SYS 40 ~ 220 mmHg
DIA 10 ~ 160 mmHg
MEAN 20 ~ 170 mmHg

Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution : 1 mmHg
Accuracy : ± 5 mmHg

TEMP
Measure and Alarm Range : 0 ~ 50 C
Resolution : 0 . 1C
Accuracy : ± 0 . 1C

Standard Parameters
ECG, RESP, TEMP, NIBP, SPO2, PR

RESP
Method : Impedance between RA-LL or RALA
Measurement Range:
Adult : 10~120 BrPM
Neonatal / Pediatric : 7~150 BrPM
Resolution : 1 BrPM
Accuracy : ± 2 BrPM

Standard Configuration
No Item Qty

  1. 1 Main Unit 1
  2. 2 5-lead ECG cable 1
  3. 3 Disposable ECG Electrode 5
  4. 4 Adult Spo2 probe 1
  5. 5 Adult NIBP cuff 1
  6. 6 NIBP extension tube 1
  7. 7 Temperature probe 1
  8. 8 Power Cable 1
  9. 9 User Manual 1
  10. 10 Fuse 3


Patient Monitor,Portable Patlent Monltor,Patlent Monltor For Adult,Patlent Monltor For Baby

Guangzhou Sonostar Technologies Co., Limited , https://www.sonoeye.com