Medical Equipment Holter System (CombiHolter)

Model NO.: CombiHolter
Full-Disclosure Transfer: Card Reader
Trademark: SHINOVA
Transport Package: Carton
Specification: CE, ISO
Origin: China
HS Code: 90181930
Model NO.: CombiHolter
Full-Disclosure Transfer: Card Reader
Trademark: SHINOVA
Transport Package: Carton
Specification: CE, ISO
Origin: China
HS Code: 90181930
3/12-Lead Holter System for 24 hours

CombiHolter Synchronized ambulatory ECG&BP 2in1 is just one of the advanced multi-parameter products manufactured. The Holter/ABPM boasts advanced high resolution Holter technology accompanied by reviewable analysis ABPM. It is widely applicable in clinical research, trial research and ECG diagnostics.

Feature:
1. 3 choices of programmable working modes: Ambulatory ECG only (3-channel or 12-lead,
Full-disclosure), ABPM only or synchronized ambulatory ECG and ABPM.
2. Small and smart, the lightweight recorder is very comfortable to wear with little or no need to alter the patient's daily activities.
3. Highly integrated design saves space and improves the performance and reliability, adding to the recorder's durability, impact and shock-resistance.
4. With graphics displayed on LCD, you can view items such as current heart rate, total of beats, ECG of each lead, current or past blood pressure, next BP testing time, battery voltage, the cuff pressure value during inflating and deflating, and the number of beats in the process of BP testing. Visual icons and menu ensure easy access. ECG can be previewed to check electrode and lead connections to ensure high quality signal recognition.
5. Highly anti-jamming electrode connection, to assure universal electrode use while chieving
High-quality signals.
6. With special amplifier and A/D convertor circuits, the recorder boasts a high fidelity of signal processing surpassing traditional standards, a 256Hz sampling frequency, a 1/1024 resolution as well as a clear and accurate display of ECG.
7. Reviewable blood pressure recording not only includes tabulated numerical data results, but also provides every artery pulsation waveform for possible review analysis.
8. Innovative intellectualized liquid control system ensures stable pressure and more accurate testing results. Quick inflation and linear deflation are completely imitates the auscultation process of physicians.
9. In the event of ECG abnormalities such as tachycardia, bradycardia and ST changes, the blood pressure testing will be initiated, thus better associating the two with each other. (Needs to be preset)
10. For a patient whose blood pressure jumps suddenly, the cuff will be automatically inflate to the proper pressure.
11. Wide dynamic range automatically adjusts to patients' blood pressures and pulsations.
12. Automatically monitors the battery and automatically stops in the event of a voltage insufficiency.
13. Large memory SD card is adopted to ensure 24-hour recording of comprehensive ECG and
ABPM without compression while providing a solid compact size. The recorded data is preserved
Without damaged in the case of voltage shortage or battery accidentally being removed.
14. Conforms to the international standards with 5 or 7 electrodes for 3-channel, and 10 lectrodes
For 12-lead.
15. Double MCU, dual sensor, dual valve to ensure that patients will not be subject to excessive
Pressure or the pressure of a long time. In line with European standards EN 60601-2-30 for
Safety requirements on blood pressure quipment, it can guarantee security in any single fault
Condition:
Results in a failure of the normal pressure regulating means;
Prevents deflation of the cuff within the specified period;
Results in a failure of the normal cuff pressurization timing.
ECG
Channels 3-channel ECG
12-lead ECG
Independent pacemaker detection
Battery voltage recording channel
Patient Input configuration 5 or 7 electrodes
10 electrodes
Blood pressure
Method of measurement Oscillometric method
Indicating range 0 ~ 300 mmHg
Recording range Systolic 50 ~ 260 mmHg
Diastolic 30 ~ 180 mmHg
Pressure precision ≤ 3 mmHg
All-purpose
Recording time 24 hours
Data transfer  
        Full-disclosure transfer Card reader
        Pre-set & real-time transfer Wireless infrared
Storage medium SD card
Memory size 256 MB or more
Batteries 4 x AA size alkaline batteries
Dimensions 124 x 68 x 31 mm
Weight 180 g (excluding batteries)
PC minimum requirements Pentium III 500 MHz or higher
1024 x 768 resolution
System requirements Windows 9x/2000/XP/Vista
3/12-Lead Holter System for 24 hours

CombiHolter Synchronized ambulatory ECG&BP 2in1 is just one of the advanced multi-parameter products manufactured. The Holter/ABPM boasts advanced high resolution Holter technology accompanied by reviewable analysis ABPM. It is widely applicable in clinical research, trial research and ECG diagnostics.

Feature:
1. 3 choices of programmable working modes: Ambulatory ECG only (3-channel or 12-lead,
Full-disclosure), ABPM only or synchronized ambulatory ECG and ABPM.
2. Small and smart, the lightweight recorder is very comfortable to wear with little or no need to alter the patient's daily activities.
3. Highly integrated design saves space and improves the performance and reliability, adding to the recorder's durability, impact and shock-resistance.
4. With graphics displayed on LCD, you can view items such as current heart rate, total of beats, ECG of each lead, current or past blood pressure, next BP testing time, battery voltage, the cuff pressure value during inflating and deflating, and the number of beats in the process of BP testing. Visual icons and menu ensure easy access. ECG can be previewed to check electrode and lead connections to ensure high quality signal recognition.
5. Highly anti-jamming electrode connection, to assure universal electrode use while chieving
High-quality signals.
6. With special amplifier and A/D convertor circuits, the recorder boasts a high fidelity of signal processing surpassing traditional standards, a 256Hz sampling frequency, a 1/1024 resolution as well as a clear and accurate display of ECG.
7. Reviewable blood pressure recording not only includes tabulated numerical data results, but also provides every artery pulsation waveform for possible review analysis.
8. Innovative intellectualized liquid control system ensures stable pressure and more accurate testing results. Quick inflation and linear deflation are completely imitates the auscultation process of physicians.
9. In the event of ECG abnormalities such as tachycardia, bradycardia and ST changes, the blood pressure testing will be initiated, thus better associating the two with each other. (Needs to be preset)
10. For a patient whose blood pressure jumps suddenly, the cuff will be automatically inflate to the proper pressure.
11. Wide dynamic range automatically adjusts to patients' blood pressures and pulsations.
12. Automatically monitors the battery and automatically stops in the event of a voltage insufficiency.
13. Large memory SD card is adopted to ensure 24-hour recording of comprehensive ECG and
ABPM without compression while providing a solid compact size. The recorded data is preserved
Without damaged in the case of voltage shortage or battery accidentally being removed.
14. Conforms to the international standards with 5 or 7 electrodes for 3-channel, and 10 lectrodes
For 12-lead.
15. Double MCU, dual sensor, dual valve to ensure that patients will not be subject to excessive
Pressure or the pressure of a long time. In line with European standards EN 60601-2-30 for
Safety requirements on blood pressure quipment, it can guarantee security in any single fault
Condition:
Results in a failure of the normal pressure regulating means;
Prevents deflation of the cuff within the specified period;
Results in a failure of the normal cuff pressurization timing.
ECG
Channels 3-channel ECG
12-lead ECG
Independent pacemaker detection
Battery voltage recording channel
Patient Input configuration 5 or 7 electrodes
10 electrodes
Blood pressure
Method of measurement Oscillometric method
Indicating range 0 ~ 300 mmHg
Recording range Systolic 50 ~ 260 mmHg
Diastolic 30 ~ 180 mmHg
Pressure precision ≤ 3 mmHg
All-purpose
Recording time 24 hours
Data transfer  
        Full-disclosure transfer Card reader
        Pre-set & real-time transfer Wireless infrared
Storage medium SD card
Memory size 256 MB or more
Batteries 4 x AA size alkaline batteries
Dimensions 124 x 68 x 31 mm
Weight 180 g (excluding batteries)
PC minimum requirements Pentium III 500 MHz or higher
1024 x 768 resolution
System requirements Windows 9x/2000/XP/Vista

Micro Pigments/Tattoo Ink

Micro Pigments,Tattoo Ink,Derma Stamp Pen

Goochie Beauty Equipment Co., Ltd. , http://www.gztattoos.com