Analysis of common problems in reverse osmosis equipment

Reverse osmosis equipment is an important part of pure water equipment, purified water equipment, and ultrapure water equipment, and it is also a problem that is more likely to occur in the operation of equipment systems. For the common problems in the daily operation of reverse osmosis equipment, we will analyze the cause of the problem for everyone to solve the equipment problem.

Low water supply pressure

(1) The feed water flow rate is not appropriate;

(2) system leakage;

(3) The water pressure at the inlet of the high pressure pump is insufficient or the pump part is leaking or leaking;

(4) Filtration of the filter element of the precision filter;

(5) The high pressure pump is faulty.

High water pressure

(1) improper adjustment of the high pressure pump outlet door;

(2) Pipe blockage from the high pressure pump to the reverse osmosis device;

(3) The concentrated water regulating door is too tight or blocked, and the concentrated water discharge flow is small;

(4) The recovery rate is too low.

Low recovery

(1) The feed water flow rate is too high;

(2) The feed water pressure or concentration is low.

High recovery rate

(1) The water supply pressure is too high;

(2) The feed water flow rate is insufficient;

High pressure drop across the reverse osmosis device

(1) The concentrated water flow rate is high;

(2) membrane element contamination;

High pressure pump stops

(1) The pump outlet pressure is too high (greater than 1.7 MPa);

(2) The water pressure at the inlet of the pump is too low (less than 0.05 MPa).

Reverse osmosis equipment production rate is reduced

(1) The feed water temperature is low;

(2) low water supply pressure;

(3) The concentration of concentrated water is too high to cause high osmotic pressure;

(4) Membrane fouling.

Reverse osmosis equipment increases water production

(1) The water supply pressure is high;

(2) The feed water temperature is high.

The water conductivity and concentrated water conductivity of reverse osmosis equipment increase simultaneously

(1) Contamination of concentrated water pipeline or concentrated water regulating valve;

(2) The recovery rate is too high.

The water conductivity is high, the conductivity of concentrated water is also high, and the pressure drop is high in each section.

(1) Membrane element contamination

(2) Limiting the concentration of concentrated water

High water conductivity, increased pressure drop across each pressure vessel, low product water flow

Membrane element contamination

The pressure drop at both ends of each pressure vessel is large, the product water flow is low, and the product water conductivity is increased.

Membrane element channel contamination, blockage

Herb Extract

Herb extract we mainly supply are monk fruit extract, shiitake mushroom extract, reshi mushroom extract and other mushroom extract like lion`s mane extract. The main active ingredient among those powders are polysaccharides, beta glucan and so on. And monk fruit extract is one of our hot selling natural sweetener which can be added in very wide range of food and beverage. Unlike sugar, it is a kind of non- nutritive sweetener which is low in calories and high in sweetness, welcome to reach us for more information.