Solid phase extraction method for detection of sulfonamides in animal-derived foods (SilibaseTM ALN)
Solid phase extraction method for detection of sulfonamides in animal-derived foods (SilibaseTM ALN)
First, the purpose of the experiment
In this experiment, solid phase extraction was used as a pretreatment method for samples, and LC-MS/MS method was used as a detection method. This method simplifies the pre-treatment of the sample and saves the amount of organic solvent.
Second, the experimental target
Sulfathiazole (CAS: 72-14-0), sulfamethazine (CAS: 127-79-7), sulfacetamide (CAS: 144-80-9), sulfapyridine (CAS: 144-83-2) , sulfamethoxazole (CAS: 127-69-5).
Third, the scope of application
The method is suitable for LC-MS/MS detection and confirmation of sulfonamides in animal-derived foods.
Fourth, the reference standard
Recommended National Standard GB/T 21316-2007 Determination of Sulfonamide Residues in Animal-derived Foods by Liquid Chromatography-Mass Spectrometry/Mass Spectrometry.
V. Experimental materials
SilibaseTM ALN solid phase extraction column 500mg/3mL.
Sixth, experimental methods
1, sample extraction
A 5 g sample will be weighed to the nearest 0.01 g. Place in a 50 mL vortex cap centrifuge tube, add 5 mL of water, and quickly mix for 1 min on a vortex mixer to completely dissolve the sample. Accurately add 15 mL of ethyl acetate, shake on a shaker for 10 min, centrifuge at 3000 r/min for 10 min, accurately pipette 12 mL of the upper layer of ethyl acetate into a 15 mL centrifuge tube, and place it in a concentrated nitrogen blower at 45 ° C to purify. Add 5 mL of water to dissolve and purify.
2, SPE column purification
The extract was passed through a neutral alumina column. After the solution was completely discharged, the column was washed with 2 x 3 mL of water, and then the column was rinsed with 5 mL of acetonitrile + water, and all the leachate was discarded. It was vacuum-dried with a vacuum pump for 10 min, and finally eluted with 6 mL of ethyl acetate. The eluent was collected in a 10 mL centrifuge tube, and dried at 45 ° C with a nitrogen purge. The volume was adjusted to 1 mL with acetonitrile + water (20 + 80). For LC-MS/MS on-board measurement.
3. LC-MS/MS conditions
Liquid chromatography-mass spectrometry/mass spectrometer
Column: C18 column: 150mm × 2.1mm, 2.0μm, or equivalent
Mobile phase: acetonitrile-0.1% formic acid
Seven, the experimental results
1, add recycling results
Different levels of tetracyclines were added to the samples, and the recovery results were as follows: (See Table 1)
Table 1 Results of tetracycline drug addition and recovery in animal tissues
sample name | Compound name | Add level (ng/mL) | Recovery rate(%) |
pork | Sulfathiazole | 50 | 84.76 |
100 | 89.44 | ||
Sulfamethazine | 50 | 81.3 | |
100 | 91.08 | ||
Sulfaacetamide | 50 | 92.92 | |
100 | 94.37 | ||
Sulfapyridine | 50 | 81.74 | |
100 | 88.09 | ||
Sulfamethoxazole | 50 | 81.81 | |
100 | 88.22 |
2, blank sample added pesticide residue chromatogram
Related Products
SilibaseTM ALN Solid Phase Extraction Column
Related applications
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Digital Radiography made affordable, Created to meet the needs of community to hospitals and private radiology practices, it enables the price-sensitive customers to join the drive to go digital.The versatile floor mounted radiography system enables you to go from film to CR to DR. Flooe-mounted easy for installation and operation.
The United-imaging is floor mounted system comprises a radiographic table with integral floor guide rail and a wallstabd. Requiring little room preparation, it is easy to install.
United-imaging according to the international advanced processing mode and standardlize design. the parts are made with precision CNC machine and moulding. Which adopt high degree of standardized, reasonable and compact structure. With reliable, durable and elegant appearance and advanced processing technology.
X-Ray Digital Machine,X-Ray Digital Machine In Medical,X-Rays Digital Medical Machine,Medical X-Ray Digital Imaging Machine
Shanghai Rocatti Biotechnology Co.,Ltd , https://www.ljdmedicals.com